LAB NOTES  

Rules / Lab Techniques

RULES

To help keep the lab functional, please follow the following guidelines. These are all just common sense and common courtesy rules, but everyone needs to be reminded of them.

All group glassware (flash columns, schlenkware, distillation heads, etc.) must be cleaned and returned immediately after use.

Group equipment (syringe pump, portable pump, balances, etc.) must be cleaned and made available within a reasonable time.

Traps on the vacuum pumps must be cleaned out if solvents are pumped in.

Chemicals should not be hoarded at the bench. Unique chemicals may be kept for a reasonable time, but common reagents should be returned to the shelves.

If you use all or close to all of a chemical, you must see that it is reordered or replaced from the stockroom.

Accidents happen, but be careful !!!

If you break something, especially group equipment, repair it immediately.

If you make a mess, clean it up.

Rotovaps must left clean for the next user. Rinse the bump trap immediately after you use it.

Glassware is much easier to clean if it is done immediately after use.

Gastight syringes are very expensive and must be treated carefully. They must not be cleaned in acid or base baths as this will destroy the plunger.

Be considerate to your labmates and help keep the lab workable !!!

 

 

LAB TECHNIQUES

 

TITRATIONS

Indicators to use for organometallic reagents in polar solvents when back titrating with a stock solution such as 1 M s-butanol in xylene:

1,10-phenanthroline
2,2'-dipyridyl
triphenylmethane

Stoichiometric indicators for organometallic reagents:

2,5-dimethoxybenzyl alcohol
4-(hydroxymethyl)biphenyl
1-(phenylamino)naphthalene
diphenylacetic acid
Salicylaldehyde phenylhydrazone

See: E. Juaristi J. Org. Chem. 1983, 48, 2603.
W. G. Kofron J. Org. Chem. 1976, 41, 1879.
B. E. Love, E. G. Jones J. Org. Chem. 1999, 64, 3755.

Titrate THF or ether solutions of lithium aluminium hydride with 9-fluorenone.
E. Brown, A. Lézé, J. Touet Tetrahedron Lett. 1991, 32, 4309.

back to top

 

 

DRYING AGENTS

Solvent Pretreatment Desiccant
Benzene Distill sodium/benzophenone
Dichloromethane calcium chloride calcium hydride
Ethanol - Magnesium
Ether calcium chloride sodium/benzophenone
Hexanes - calcium hydride
Methanol - Magnesium
Pyridine - KOH
THF KOH sodium/benzophenone
Toluene - sodium/benzophenone

For desiccant efficiencies in drying alcohols, see: R. Smithers J. Org. Chem. 1983, 48, 2420.

See also: Purification of Laboratory Chemicals, D. D. Perrin and W. L. F. Armarego, Pergamon, London, 1989.

back to top

 

 

WORKUP OF ALUMINUM BASED REDUCTIONS

A. To workup a reaction containing x g lithium aluminum hydride:
Dilute with ether and cool to 0oC
Slowly add x mL water
Add x mL 15 % aqueous sodium hydroxide
Add 3x mL water
Warm to RT and stir 15 min
Add some anhydrous magnesium sulfate
Stir 15 min and filter to remove salts

B. Ethyl acetate is a good reagent to quench lithium aluminum hydride reductions since the resultant ethanol is easy wash out.

C. To workup a reaction containing x mmol of an agent such as Dibal:
Dilute with ether and cool to 0oC
Slowly add 0.04x mL water
Add 0.04x mL 15 % aqueous sodium hydroxide
Add 0.1x mL water
Warm to RT and stir 15 min
Add some anhydrous magnesium sulfate
Stir 15 min and filter to remove salts

back to top

 

 

WORKUP TO REMOVE SOLVENTS

Dioxane, DMF, DMSO, and THF reaction solvents are all readily removed by aqueous workup rather than distillation. Add reaction mixture to solvent such as ether and wash five times with water. Changes must be made if desired product is soluble in water or insoluble in ether.

back to top

 

 

WORKUP TO REMOVE AMINES

Acidic: Wash with 10% aqueous HCl solution.
Non-Acidic: Wash with aqueous CuSO4 to remove amines as R3N.CuSO4 complex.

back to top

 

 

WORKUP TO REMOVE ORGANOTIN RESIDUES

Byproducts of tin based reactions such as Bu3SnBr can be removed by treatment with AlMe3 to create the nonpolar Bu3SnMe or NaOH to create the polar Bu3SnOH. See: P. Renaud, E. Lacote, L. Quaranta Tetrahedron Lett. 1998, 39, 2123.

back to top

 

 

WORKUP TO REMOVE METAL SALTS

Many transition metals can be removed by precipitation of the sulfides. Wash with aqueous sodium sulfide. If necessary, adjust pH to create H2S.

Some transition metals can be removed by aqueous extraction with tris(hydroxymethyl)phosphine. See: R. H. Grubs Tetrahedron Lett. 1999, 40, 4137.

back to top

 

 

HEATING BATHS

Water Usable to about 80oC

Mineral Oil Usable to about 150oC

Silicone Oil Usable to about 250oC

Phosphorous acids Usable to about 250oC (20% H3PO3, 80% H3PO4)

Wood's Metal Usable to about 350oC (50% Bi, 25% Pb, 12.5% Sn, 12.5% Cd)

Sand Usable to about 1000oC

 

back to top

 

CLEANING BATHS

General Bath to Remove Organic Residues:
Add about a half an inch of KOH to a tank of isopropanol

Acid Bath:
Use 3 M HCl

Chromic Acid Bath: (Due to environmental concerns, this is a last choice. However, the solution can be reused many times, thus minimizing what is washed down the drain.)
46 g Na2Cr2O7
230 mL H2O
400 mL H2SO4

back to top